Hatch Cant Close (332) [FusionPort]

Created by Franziska Möller, Modified on Tue, 21 Oct at 3:29 PM by Franziska Möller

Error Explanation: Hatch initialization movement did not complete correctly, it should meet mechanical resistance and magnet sensor shall be registered closed. 

Possible Causes: 
1) Hatch is physically blocked from closing correctly.
2) Hatch panel is separated from it's magnet.
3) The hatch rail/guides causes too much friction, stopping the hatch initalization before it is completely closed. 
4) If power was just turned on, the capacitors needs to be charged. 

Solutions:

1) Clear any obstructions blocking the hatch from closing, then try to start the Port again.

2) Re-attach hatch panel to magnet by pressing the E-Stop, then manually pushing the hatch panel up until the panel re-attaches     the magnet (a click will be heard / felt). Then try to start the Port again.

3) Feel for any unusual friction in the movement of the hatch panel. Too much friction may mean a belt tension issue that must     be corrected before trying to use the or
4) Allow the Fusion Port to remain powered-on and not E-Stopped for 1-2 minutes, then try to start the Port again.

Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons